SPECIFICATIONS
|
MODEL
|
7470
|
7472
|
7473
|
7474
|
Output Rating
|
10KVAC/20mA
|
12KVDC/10mA
|
20KVAC/10mA
|
20KVDC/5mA
|
AC WITHSTAND VOLTAGE (7470&7473)
|
|
Range
|
Resolution
|
Accuracy
|
Output Voltage, ACV (for 7473)
|
0 - 20000
|
10
|
±(2% of setting + 20V)
|
Output Voltage, ACV (for 7470)
|
0 - 10000
|
10
|
±(2% of setting + 10V)
|
Output Frequency
|
50Hz/60Hz ±100ppm, User Selection
|
Output Waveform
|
Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
|
Output Regulation
|
± (1% of output + 10V), From no load to full load
|
SETTINGS
|
Hi / Lo -Limit AC Current, mA (for 7473)
|
0 - 9.999
|
0.001
|
±(2% of setting + 2counts)
|
Hi / Lo -Limit AC Current, mA (for 7470)
|
0 - 9.999/10.00 - 20.00
|
0.001/0.01
|
±(2% of setting + 2counts)
|
Ramp Up Time, second
|
0.3 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
Ramp Down Time, second
|
0.0 - 999.9
|
0.1
|
Dwell Time
|
0, 0.3 - 999.9 sec (0=continuous)
|
0.1
|
0, 0.1 - 999.9 min (0=continuous)
|
0.1
|
0, 0.1 - 999.9 hr (0=continuous)
|
0.1
|
Cycle Test
|
0 - 9999 Times, (0=continuous)
|
Arc Detection
|
Range 1 - 7 > 15kV , Range 1 - 9 < 15kV
|
AC Current Offset, mA
|
0 - 2.000 or Auto Set ( Option )
|
MEASUREMENT
|
AC Voltage, KV (for 7473)
|
0 - 20.00
|
0.01
|
±(2% of reading + 2counts)
|
AC Voltage, KV (for 7470)
|
0 - 10.00
|
0.01
|
±(2% of reading + 2counts)
|
AC Current Range, mA
|
0-3.500
|
0.001
|
±(2% of reading + 3counts)
|
3.00-10.00 (for 7473)
|
0.01
|
3.00-20.00 (for 7470)
|
0.01
|
DC WITHSTAND VOLTAGE (7472&7474)
|
Output Voltage, DCV (for 7474)
|
0 - 20000
|
10
|
±(2% of setting + 20V)
|
Output Voltage, DCV (for 7472)
|
0 - 12000
|
10
|
±(2% of setting + 10V)
|
Output Ripple
|
<5%(在20KV/5000μA for 7474, 12KV/9999μA at Resistive Load for 7472)
|
SETTINGS
|
Hi / Lo -Limit DC Current, μA (for 7474)
|
0.0 - 999.9/1000 - 5000
|
0.1/1
|
±(2% of setting + 2counts)
|
Hi / Lo -Limit DC Current, μA (for 7472)
|
0.0 - 999.9/1000 - 9999
|
0.1/1
|
±(2% of setting + 2counts)
|
Ramp Up Time, second
|
0.4 - 999.9
|
0.1
|
±(0.1% + 0.05sec)
|
Ramp Down Time, second
|
0.0,1.0 - 999.9
|
0.1
|
Dwell Time
|
0, 0.4 - 999.9 sec (0=continuous)
|
0.1
|
0, 0.1 - 999.9 min (0=continuous)
|
0.1
|
0, 0.1 - 999.9 hr (0=continuous)
|
0.1
|
Cycle Test
|
0 - 9999 Times, (0=continuous)
|
Arc Detection
|
Range 1 - 9 (9 is the most sensitivity)
|
DC Current Offset, μA
|
0.0 - 200.0 or Auto Set (Option )
|
Ramp High Current
|
ON/OFF, User Selection
|
Charge - Low Current, μA
|
0.0 - 350.0 or Auto Set
|
Discharge Time
|
< 200 msec
|
Maximum Capacitive Load
|
1.5μF < 2KV 0.15μF < 8KV 0.12μF < 14KV 0.08μF < 20KV
|
0.28μF < 4KV 0.15μF < 10KV 0.1μF < 16KV
|
0.18μF < 6KV 0.12μF < 12KV 0.08μF < 18KV
|
MEASUREMENT
|
DC Voltage, KV (for 7474)
|
0 - 20.00
|
0.01
|
±(1.5% of reading + 2count)
|
DC Voltage, KV (for 7472)
|
0 - 10.00
|
0.01
|
±(1.5% of reading + 2count)
|
DC Current Range, μA
|
0-350.0
|
0.1
|
± (2% of reading + 3counts)
|
300-3500
|
1
|
3000 - 5000 (for 7474)
3000-9999 (for 7472)
|
10
|
GENERAL
|
Input Voltage AC
|
115/230VAC ± 15% , 50/60Hz ± 5% Fuse: 6.3A Slow
|
PLC Remote Control
|
Input : Test , Reset , Memory1.2.3 ,Interlock
|
Output : Pass , Fail , Processing
|
Safety
|
Smart-GFI Function (<1mA)
|
Memory
|
50 memories
|
Display
|
20*2 LCD with back light
|
Key Lock
|
To prevent unauthorized alteration of the test Parameters
|
Calibration
|
Build-in software and external calibrated meters
|
Interface
|
RS232/GPIB /Printer Card (Option)
|
Alarm Volume Setting
|
10 ranges set by the numeric keys on the front panel
|
Environment
|
0-40℃, 20-80%RH
|
Dimension
|
430mm(W)×133mm(H)×400mm(D)
|
Net Weight
|
24Kg
|
24Kg
|
22.5Kg
|
23Kg
|
STANDARD ACCESSORIES
|
Power Cord (10A)
|
×1
|
Fuses
|
×2 (Including a spare contained in the fuse holder)
|
Interlock Disable Key (1505)
|
×1
|
Hipot Test Lead ,1.5m (1142)
|
-
|
-
|
×1
|
×1
|
Hipot Test Lead ,1.5m (1143)
|
×1
|
×1
|
-
|
-
|
Hipot Return Lead ,1.8m (1144)
|
×1
|
×1
|
×1
|
×1
|